●ON/OFF Settings
When the thermostat is powered on, it displays the default information. Press again to toggle it off. ● Temperature Setting While in default display mode, press ˄ or ˅ to set the target floor temperature. After adjusting the temperature, the thermostat will automatically save the setting in 3 seconds if no other buttons are pressed. The temperature range is adjustable from 5~32℃ (41-90℉). ● Call for Heat 1. When the floor’s temperature drops 1℃/2℉ lower than the preset temperature, the thermostat will call for heat and the display will show “Heat on”. 2. When the floor’s temperature is 1℃/2℉ higher than the preset temperature, the thermostat will stop calling for heat and the “Heat on” message will disappear |
When the thermostat is OFF: press ˅ for 3 seconds to enter the configuration interface. Default values and options are below:
NO. | Parameter | Settings Range | Default | Note |
000 | Temperature Calibration | -5~5℃(-10~10℉) | 0 | |
001 | Backlight | 0,1 | 0 | 0: OFF 1: ON |
002 | Celsius/Fahrenheit | 0,1 | 1 | 0: ℃ 1: ℉ |
003 | Key Volume | 0,1 | 1 | 0: Mute 1: ON |
004 | Thermostat ON or OFF after power loss | 0,1,2 | 0 | 0: OFF 1: ON 2: Last State |
005 | Version No. | 10 | 10 | |
006 | Factory Reset | 0~255 | 52 | To reset change to 55 and press |